Category Archives

3 Articles

Main Handover Events for 3G (UTRA FDD)

In GSM there was a dedicated channel for periodically reporting the controller (BSC) with the current situation faced by UE. But in 3G, the measurements can be set to Periodic or Event-triggered. Almost unanmously, all operators decided for Event-triggered measurements.

The following categories of measurement events are defined for UTRA FDD

  • 1-series (event 1A to 1F):
    • Intra-frequency events
  • 2-series (event 2A to 2F):
    • inter-frequency events
  • 3-series (event 3A to 3D):
    • inter-RAT events
  • 4-series (event 4A and 4B):
    • traffic volume events
  • 5-series (event 5A):
    • quality event
  • 6-series (event 6A to 6G):
    • UE internal events
  • 7-series (event 7A to 7C):
    • UE positioning events

From all the above events, the most commonly discussed are the Series 1 Events because they lead to start and stop of Soft Handover. Event 1A, 1B and 1C are the king of all events.

  • 1A:
    • A Primary CPICH enters the reporting range.
  • 1B
    • A primary CPICH leaves the reporting range. Similar concept as in 1A.
  • 1C:
    • A non-active primary CPICH becomes better than an active primary CPICH
  • 1D:
    • Change of best cell
  • 1E:
    • A Primary CPICH becomes better than an absolute threshold
  • 1F:
    • A Primary CPICH becomes worse than an absolute threshold

More about these can be read in the Chapter 5 of book under Radio Resource Management Chapter.

0 views

UMTS Sensitivity

Quite often when someone has worked with 2G for a while, his mind starts relating all radio issues to RxLev (dBm) of the BCCH Channel.

In 3G, BCCH is purely used to carry the Cell Specific System Information in he form of SIBs. The RF signal strength is measured using CPICH power.

For calculating the Sensitivity, we will stick to the basic formula :

Rx Sensitivity = Thermal Noise + NF (of Receiver) + SNR required





  • Thermal Noise = Botlzman’s Costant (Joules/kelvin) * Temp (Kelvin) * BW (Hz)
  • Where Botlzman’s Costant = 1.38E-23 J/K
  • where Temp is temperature of the environment (in Kelvin)
  • Frequency part is different in GSM and UMTS. In GSM everything happens in 200 KHz, whereas in 3G Noise is measured over the efffective BW of 3.84 MHz.

Thermal Noise in 2G : -120 dBm

Thermal Noise in 3G : -108 dBm

0 views